Design capabilities
From the design detail to engineering and shop drawings, every sheet is drawn to ISO 128, ISO 129 and ISO 7200, coordinated across architecture, structure and engineering, and issued under EN ISO 19650. Where the project requires, the same design is delivered to ГОСТ, ՀՀՇՆ or UAE rules. Open any sheet at full size and see for yourself.
The sheets on this page are illustrative samples drawn by PIALA for this purpose. They contain no client data and are not for construction.
The envelope, structure and interiors at a glance
Every junction is keyed, dimensioned and referenced to its full detail sheet, so a contractor finds the right detail in seconds.
Sixteen junctions, drawn in full
Each sheet shows the junction at 1:2 to 1:10, with a 1:1 enlargement where a joint is smaller than 5 mm on paper, every fixing specified, the installation sequence and the joint rule. Select a sheet to read it at full size.
Services fixed in zones before a single duct is routed
Gravity pipes take the top band because their falls cannot move. Ducts, pipework and trays sit below, with a band left for access and tolerance. Every support hangs from the slab, and every penetration is sealed with a tested system matched to the wall class.
Every point placed, every circuit calculated, energy proven
A typical guest room: lighting and small power with circuit and height beside each point, the single-line diagram with voltage drop checked to HD 60364-5-52, and fire alarm and low-current layouts. U-values to EN ISO 6946, 13370 and 10077-1 and heat loads to EN 12831-1 are calculated, never assumed.
From the detail to the workshop
A shop drawing package lets the fabricator cut, weld, coat, pack and install without a single phone call. This sample develops one design detail, the glulam beam connection S-5604, into seven sheets for the steel workshop, the timber CNC line and the site team.
The shop drawing refines the design. It never changes it.
Every dimension, product and code on the design detail is compared with the shop drawing, line by line. A development is listed as a deviation for the engineer to accept in writing. Design forces and calculations that do not exist yet are listed as hold points with an owner and a date, never guessed.
One drawing, four rule books
We draw to the standard of the place where the building stands. Editions are confirmed for each project, and licensed sign-off stays with the architect or engineer of record where the law requires it.
| Topic | ISO / EN — Europe | ГОСТ / СПДС — CIS | ՀՀՇՆ — Armenia | UAE |
|---|---|---|---|---|
| Lines and lettering | ISO 128, ISO 3098 | ГОСТ 2.303, 2.304 | ГОСТ 2.303, 2.304 | BS EN ISO 128 practice |
| Dimensions and scales | ISO 129-1, ISO 5455 | ГОСТ 2.307, 2.302 | ГОСТ 2.307 | ISO / BS practice |
| Sheets and title block | ISO 5457, ISO 7200 | ГОСТ 21.101, form 3 | ГОСТ 21.101, Armenian text | Consultant or authority format |
| Set naming | EN ISO 19650 | ГОСТ 21.101 marks (АР, КЖ, ОВ) | ГОСТ marks + ՀՀՇՆ | Client / ISO 19650 |
| Structure and seismic | Eurocodes EN 1990–1998 | СП, ГОСТ 21.501 | ՀՀՇՆ seismic code | DBC / ADIBC |
| Fire | EN 13501, EN 1366 | СП, technical regulation | ՀՀՇՆ fire norms | UAE Fire and Life Safety Code |
| Electrical | IEC 60617, HD 60364 | ГОСТ 21.210, 21.608 | ГОСТ 21.608 + ՀՀՇՆ | DEWA / ADDC regulations |
| HVAC and plumbing | EN 16798-1, EN 12056, EN 806 | ГОСТ 21.602, 21.601 | ГОСТ 21.602, 21.601 | DBC + ASHRAE practice |
The number tells you what the sheet is
File names follow EN ISO 19650-2. Sheet numbers run in fixed ranges: 1000 plans, 3000 sections, 5100–5800 details by element, 6000 schedules, 7000 production, 8000 coordination. Every sheet carries its status and revision, and every issue its transmittal.
Request the complete PDF set
The full A3 set at print resolution, with the shop drawing package and its DXF files. Tell us about your project and we will send it by email.